Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Sends a message when the button is pressed. Can recognize various types of button presses - quite simple with many use cases ranging from security to eldercare.

Expand
titlePress me
Include Page
INCLDOC:0x01 Press me/API 6 User Modes (INCL)
INCLDOC:0x01 Press me/API 6 User Modes (INCL)

...

Guard me sends messages once the object moves, vibrates or changes position. After the alert is sent, the device is inert for the duration of the sleep time to prevent draining the battery.

Expand
titleGuard me
Include Page
INCLDOC:0x02 Guard me/API 6 User Modes (INCL)
INCLDOC:0x02 Guard me/API 6 User Modes (INCL)

...

Track me sends a message when the monitored object starts moving and also sends one when the movement stops and the device does not move for an adjustable time period.

Expand
titleTrack me
Include Page
INCLDOC:0x03 Track me/API 6 User Modes (INCL)
INCLDOC:0x03 Track me/API 6 User Modes (INCL)

...

Trace me sends messages while the object is moving and stops sending them when it’s still. While moving, it periodically sends a message (the period length is defined in the Tracing delay register) so you can trace the monitored object. No more messages are sent after stop of movement is detected and reported.

Expand
titleTrace me
Include Page
INCLDOC:0x04 Trace me/API 6 User Modes INCL
INCLDOC:0x04 Trace me/API 6 User Modes INCL

...

Using the accelerometer, this mode monitors occurrence of vibration and periodically reports when the monitored object was vibrating and when it was not in a predefined time window.

Expand
titleMonitor me
Include Page
INCLDOC:0x05 Monitor me/API 6 User Modes (INCL)
INCLDOC:0x05 Monitor me/API 6 User Modes (INCL)

...

Reports movement of an object and once the movement stops, reports precise position through accelerometer data. You can use the data to determine whether the object was displaced or not.

Expand
titlePut me back
Include Page
INCLDOC:0x06 Put me back/API 6 User Modes (INCL)
INCLDOC:0x06 Put me back/API 6 User Modes (INCL)

...

Don’t drop me behaves similarly to Guard me except for its event (uplink message) is triggered by faster acceleration of the accelerometer in one of its axis and not just movement detection. Drop alert detection threshold can be defined.

Warning

Please note this mode should not be used on boards with an opto pin (SimpleIndustry with 2 external sensors) because of accelerometer consumption. Please contact us at ask.simplehw.eu for more information.

Expand
titleDon't drop me
Include Page
INCLDOC:0x07 Don't drop me/API 6 User Modes (INCL)
INCLDOC:0x07 Don't drop me/API 6 User Modes (INCL)

...

Sends a timeline of when and how long the reed contact was opened and when and how long it was closed, 8 time periods are sent in total. Useful for creating a history of e.g. door usage and more.

Expand
titleReed switch on/off with redundancy
Include Page
INCLDOC:0x08 Reed switch on/off with redundancy/API 6 User Modes (INCL)
INCLDOC:0x08 Reed switch on/off with redundancy/API 6 User Modes (INCL)

...

Detects doors opening and closing using the accelerometer and the magnetometer.

Expand
titleDoor mode
Include Page
INCLDOC:0x09 Door mode/API 6 User Modes (INCL)
INCLDOC:0x09 Door mode/API 6 User Modes (INCL)

...

This mode lets you know when a water leak has occurred and also when water is no longer detected. Position is monitored and any tilt over a predefined threshold (up to 180 degrees) is reported. If the device returns to the original position, the device will send a message too.

Note

Leakage Leak detector is only for the SimpleLeak! No other device works properly in this mode.

Expand
titleLeak detector
Include Page
INCLDOC:0x0A Leak detector/API 6 User Modes (INCL)
INCLDOC:0x0A Leak detector/API 6 User Modes (INCL)

...

A mode created to literally show off. Will send some mode-specific events from Press me (0x01) and all mode-specific events from Don’t drop me (0x07), Reed on/off (0x0C) and Light on/off (0x0D) together with appended payload with voltage, temperature and accelerometer data. WiFi is used in one event.

Expand
titleDemo
Include Page
INCLDOC:0x0B Demo Mode/API 6 User Modes (INCL)
INCLDOC:0x0B Demo Mode/API 6 User Modes (INCL)

...

Sends a message when the reed contact is switched on by a magnet and also sends one when the sensor is switched off because the nearby magnetic field is no longer detected.

Expand
titleReed switch on/off
Include Page
INCLDOC:0x0C Reed switch on/off/API 6 User Modes (INCL)
INCLDOC:0x0C Reed switch on/off/API 6 User Modes (INCL)

...

Detects light - a message is sent every time a predefined threshold (% of light detected) is crossed either way. Can be set up to detect a very low light percentage threshold - darkness and extreme darkness (useful for monitoring package opening in the night).

Expand
titleLight on/off
Include Page
INCLDOC:0x0D Light on/off/API 6 User Modes (INCL)
INCLDOC:0x0D Light on/off/API 6 User Modes (INCL)

...

Intended for long-term monitoring of temperature exception occurrences - in this mode, temperature exception is defined as temperature above or below the three predefined temperature thresholds A, B and C. Will send an event with 5 exceptions and the duration of each exception. Every exception with its duration will take up two bytes of the payload for a total of 12 bytes. The thresholds are encoded in SimpleTemp.

Expand
titleTemperature threshold with redundancy
Include Page
INCLDOC:0x0E Temperature threshold pipeline/API 6 User Modes (INCL)
INCLDOC:0x0E Temperature threshold pipeline/API 6 User Modes (INCL)

...

Intended for long-term monitoring of temperature exception occurrences - in this mode, temperature exception is defined as temperature above the predefined temperature delta. Will send an event with 5 exceptions and the duration of each exception. Every exception with its duration will take up two bytes of the payload for a total of 12 bytes (mode and event bytes included). The delta is encoded in SimpleTemp.

Expand
titleTemperature change with redundancy
Include Page
INCLDOC:0x0F Temperature delta pipeline/API 6 User Modes (INCL)
INCLDOC:0x0F Temperature delta pipeline/API 6 User Modes (INCL)

...

This mode sends an alert every time the measured temperature is above or below any of three predefined temperature thresholds A, B or C. The thresholds are encoded in SimpleTemp.

Expand
titleTemperature threshold alert
Include Page
INCLDOC:0x10 Temperature threshold alert/API 6 User Modes (INCL)
INCLDOC:0x10 Temperature threshold alert/API 6 User Modes (INCL)

...

This mode sends an alert every time the measured temperature is above the predefined temperature delta. The delta is encoded in SimpleTemp.

Expand
titleTemperature change alert
Include Page
INCLDOC:0x11 Temperature delta alert/API 6 User Modes (INCL)
INCLDOC:0x11 Temperature delta alert/API 6 User Modes (INCL)

...

Counts the number of reed contact switches and can report them in various ways. Very useful when you need to count e.g. rotation, door openings and closings etc.

Expand
titleReed switch counter
Include Page
INCLDOC:0x13 Reed counter/API 6 User Modes (INCL)
INCLDOC:0x13 Reed counter/API 6 User Modes (INCL)

...

Sends 2 MAC addresses regularly in a predefined period. Precise localisation with an emphasis on using as little battery life as possible as the MACs are sent in one message.

Expand
titleStupid mode 1
Include Page
INCLDOC:0x12 Stupid mode 1 (2 MAC addresses)
INCLDOC:0x12 Stupid mode 1 (2 MAC addresses)

...

This mode doesn’t send any payload, only Sigfox metadata. The messages are sent periodically and the time period can be adjusted. Used for Sigfox localisation with the lowest battery consumption possible.

Expand
titleStupid mode 2
Include Page
INCLDOC:0x61 Stupid mode 2/API 6 User Modes (INCL)
INCLDOC:0x61 Stupid mode 2/API 6 User Modes (INCL)

...